Skip to content

Approach to Hypoxemia

Approach diagram

Original hypoxemia figure from PDF page 118.

Enlarge original diagram

Diagram in text

  • Increased A–a gradient → administer 100% O₂
  • PaO₂ improves → V/Q mismatch: obstructive lung disease (COPD, asthma); pulmonary vascular disease (PE); interstitial lung disease.
  • PaO₂ does not improve → shunt: anatomic (intracardiac shunt, AVMs); physiologic (atelectasis, pneumonia, ARDS).
  • Normal A–a gradient
  • Increased PaCO₂ → hypoventilation: CNS depression; obesity hypoventilation syndrome; ALS (impaired neural conductions); myasthenia gravis (muscular weakness).
  • Normal PaCO₂ → low PaO₂ (high altitude).

Definitions

  • Alveolar to arterial (A-a) oxygen gradient: PAO2 -(PaO2), difference between amount of oxygen in alveoli (PAO2) and amount of oxygen dissolved in plasma (PaO2)
  • PAO2 = (FiO2 x (Patm – PH2O)) – (PaCO2/RespQ)
  • PAO2 partial pressure of alveolar oxygen, FiO2 fraction of inspired oxygen (0.21), Patm atmospheric pressure (760mmHg), PH2O H2O pressure in the alveolus (47mmHg), PaCO2 from the ABG, RespQ respiratory quotient (0.8)

Management

  • Reverse underlying pathology
  • Oxygen Therapy: to maintain oxygenation above PaO2 ≥ 60 mmHg (in most cases)
  • Low-flow (e.g., nasal cannula, simple mask, reservoir mask) vs high-flow (e.g., venturi masks) systems depends on clinical circumstances
  • Improves hypoxemia in hypoventilation, V/Q mismatch, diffusion impairment and low PiO2
  • Minimal impact on hypoxemia in shunt
  • Ventilation, BiPAP, and PEEP/CPAP: for more severe hypoxemia; to recruit alveoli and redistribute lung fluid
  • Improves hypoxemia in hypoventilation, intrapulmonary shunt (except one-sided) and V/Q mismatch
  • Worsens hypoxemia in right to left shunt
  • Minimal impact on hypoxemia in low FiO2
  • Intubation may be required if no improvement in PaO2 with these methods
  • Improve Cardiac Output: +/- hemodynamic support (fluids, vasopressors, inotropes), reduce O2 requirements
  • Improves hypoxemia in intrapulmonary shunt and V/Q mismatch
  • Worsens hypoxemia in right to left shunt
  • Minimal impact on hypoxemia in hypoventilation and low FiO2

References

Original Respirology reference list. The source provides references for the specialty as a whole.